COMPLETE OVER VIEW OF ACCESSORIES · Multi-Branch Systems

1. STAINLESS STEEL FUNNELS: 40, 100, 500 ml
DESCRIPTION
![]() |
For colony and particle counting. |
- Safe & reliable
- Autoclavable
- Sanitizable by flaming
- Easy to use
- Low consumable cost
- For adapting to multi-branch system use adapter A840.
TECHNICAL SPECIFICATIONS
| Material | Stainless Steel AISI 304,B.S. 304S31 |
|---|---|
| Capacity | 40 ml, 100 ml, 500 ml |
| Filter diameter | 47 mm or 50 mm |
| Filtration area | 12.5 cm² |
| Max. operating pressure | Vacuum only |
| Sanitization | By flaming |
| Sterilization | By autoclaving (134 ºC max.) By dry heat (180 ºC) |
ORDERING INFO
RF040 Stainless Steal capacity 40 ml with clamp RF100065 Stainless Steal capacity 100 ml with clamp RF500002 Stainless Steal capacity 500 ml with clamp RF100063 Stainless steel lid ( 77.2 + 85.8 mm) for 100 ml funnel RF100064 Silicone lead seal for 100 ml funnel RF500001 Stainless steel lid for 500 ml funnel RF500003 Silicone lead seal ( 122 + 131 mm) for 500 ml funnel
2. GLASS FILTER HOLDER: 30, 250 ml
DESCRIPTION
![]() |
For easy particulate analysis and colony and particle counting and for hybridization test. |
- Safe & reliable
- Autoclavable
- Sanitizable by flaming
- Easy to use
- Low consumable cost.
- For adapting to multi-branch system use adapter A836 for EFV030 and A837 for EFV250.
TECHNICAL SPECIFICATIONS
| Material | Funnels and base : Borosilicate glass, 3.3 Clamp: Anodized aluminium Filter support : PTFE / Borosilicate glass, 3.3 Lid (only for EFV250) : Silicone Gasket: Silicone O-ring (25 x 3 mm for EFV030 and 45 x 3 mm for EFV250) |
|---|---|
| Max. operating pressure | Vacuum only |
| Sterilization | By autoclaving (134 ºC max.) By dry heat (180 ºC) |
EFV030 / EFV250 |
|
| Capacity | 30 ml / 250 ml |
| Filter diameter | 25 mm / 47 or 50 mm |
| Filtration area | 3 cm² / 12.5 cm² |
| Outlet (outer diameter) | 12 mm / 15 mm |
ORDERING INFO
EFV030 Glass filter holder 30 ml EFV250 Glass filter holder 250 ml
ADAPTERS FOR GLASS FILTER HOLDER: 30, 250 ml TO MULTI-BRANCH SYSTEM 2.1. ADAPTER A836, A837
DESCRIPTION
For adapting a glass holder EFV030 and EFV250 on the multi-branch systems.
TECHNICAL SPECIFICATIONS
Material Base : AISI 304 stainless steel
Stopper: SiliconeMax. operating pressure Vacuum only Sterilization By autoclaving (134 ºC max.)
By dry heat (180 ºC)Outlet TR 20 x 2 mm male thread
ORDERING INFO
A836 Adapter with 11 mm opening in stopper, for using filter holder EFV030 A836280 Replacement stopper for EFV030 A837 Adapter with 14 mm opening in stopper, for using filter holder EFV250 A837280 Replacement stopper for EFV250
3. POLICARBONATE FILTER HOLDERS
DESCRIPTION
![]() |
For colony and particle counting, ideal for microbiological and analytical testing outside the laboratory. |
- Autoclavable
- Low purchase price and cost of investment and consumables.
- Can be used to a multi-branch systen directly, without adapter.
TECHNICAL SPECIFICATIONS
| Material | Housing : Polycarbonate Filter support : Polypropylene Gasket : Silicone O-rings (40 x 5mm, 80 x 3 mm, 14 x 2 mm) |
|---|---|
| Capacity | 250 ml |
| Filter diameter | 47 mm (prefilter 37 mm) |
| Filtration area | 11.5 cm² |
| Max. operating pressure | Vacuum or 2 bar (29 psi) pressure max. |
| Sterilization | By autoclaving (121 ºC max.) |
| Outlet | TR 20 x2 mm male thread |
ORDERING INFO
Whitout adapter to use in multi-branch system.
4. MONITOR READY TO USE
![]() |
For colony counting, for microbiological testing of pharmaceuticals, cosmetics, food, beverages, water and other liquids. |
- Ready to connect, easy to use
- With an incorporated membrane filter and cellulose pad
- Just remove the 100 ml funnel to convert to Petri dish.
- Ensures the identification of all colonies.
- Monitors with cellulose nitrate membranes assure effective retention with high flow rates and optimum colony growth.
- Monitors with regenerated cellulose are ideal for bioburden-testing in the veterinary sector.
- Disposable sterile, individually packaged or in trays.
- For adapting to multi-branch, there're two posibilities: adapter A840 plus adapter A414 or adapter A835.
TECHNICAL SPECIFICATIONS
| Material | Housing : Polystyrene Membrane filter: cellulose nitrate: white, green or grey Pad: Cellulose Plug adapter: Polyethylene |
|---|---|
| Capacity | 100 ml, 10 ml graduations |
| Pore sizes | 0.2 µm, 0.45 µm, 0.8 µm |
| Filter diameter | 47 mm |
| Filtration area | 14.5 cm² |
| Max. operating pressure | Vacuum only |
| Sterilization | Gamma irradiation |
ORDERING INFO
MATERIAL PORE ( µm) ∅ | (mm) COLOUR/GRID PRESENTATION CODE Cellulose nitrate 0.2 47 White / Black Sterile, individually packaged , 48 units ENCS02047BC Cellulose nitrate 0.45 47 White / Black Sterile, individually packaged , 48 units ENCS04547BC Cellulose nitrate 0.45 47 Green / Green Sterile, individually packaged , 48 units ENCS04547VVC Cellulose nitrate 0.45 47 Black / White Sterile, individually packaged , 48 units ENCS04547NC Cellulose nitrate 0.20 47 White / Black Sterile, packaged in trays ENCS02047BCT Cellulose nitrate 0.45 High Flow 47 White / Black Sterile, packaged in trays ENCS045HF47BCT Cellulose nitrate 0.45 47 White / Black Sterile, packaged in trays ENCS04547BCT Cellulose nitrate 0.45 47 Green / Green Sterile, packaged in trays ENCS04547VVCT Cellulose nitrate 0.45 47 Black / White Sterile, packaged in trays ENCS04547NCT Cellulose nitrate 0.8 47 Black / White Sterile, packaged in trays ENCS08047NCT Cellulose nitrate 0.45 47 White Sterile, packaged in trays ECRS04547BLT
ADAPTERS FOR MONITOR READY TO USE TO MULTI-BRANCH SYSTEM 4.1.1ADAPTER A840
DESCRIPTION
For adapting a monitor ready to use on the on the multi-branch systems with adapter A414.
The stainless steel frit ensures uniform distribution of microorganismos and particles on the membrane filter surface.
TECHNICAL SPECIFICATIONS
Material Stainless Steel AISI 304,B.S. 304S31
Gasket : Silicone flat gasket (41 x 50 x 1 mm)Filter diameter 47 mm or 50 mm Filtration area 12.5 cm² Max. operating pressure Vacuum only Sanitization By flaming Sterilization By autoclaving (134 ºC max.)
By dry heat (180 ºC)Outlet TR 20 x 2 mm male thread with DN 24 ( aprox. 24 mm) hexagonal nut
ORDERING INFO
A840 Single base for stainless steel manifolds RF102 Stainless steel frit, Ø 50 mm RF103 Stainless steel frit, Ø 47 mm RF124 Silicone flat gasket RF104 PTFE flat gasket RF274 Silicone O–ring 4.1.2 ADAPTER A414
DESCRIPTION
For adapting a monitor ready to use onto the filter support A840 of the multi-branch system or onto frit of manifolds.
TECHNICAL SPECIFICATIONS
Material Silicone Max. operating pressure Vacuum only Sterilization By autoclaving (134 ºC max.)
ORDERING INFO
A414 Adapter of silicone
ADAPTERS FOR MONITOR READY TO USE TO MULTI-BRANCH SYSTEM 4.2. ADAPTER A835
DESCRIPTION
For adapting a monitor on a multi-branch system. This adapter is attached to the polyethylene adapter ( included in the monitors packaging) which is connected to the outlet of the monitor.
TECHNICAL SPECIFICATIONS
Material Base : AISI 304 stainless steel
Stopper: SiliconeMax. operating pressure Vacuum only Sterilization By autoclaving (134 ºC max.)
By dry heat (180 ºC)Outlet TR 20 x 2 mm male thread
ORDERING INFO
A835 Adapter with 10 mm opening in stopper A835279 Replacement stopper for A835
5. POLYPROPYLENE FUNNEL
For colony and particle counting.
- Suitable for microbiological analysis of relatively large sample volumes that have a low number of microbes.
- Also suitable for testing smaller volumes by placing a sample in a few ml of sterile physiological NaCl solution.
- Specially designed for microbiological testing of pharmaceuticals, food, beverages, water and other liquids.
- Designed to be placed onto bases of a manifolds and multi-branch system.
- Graduated at 50, 100, 150 and 200 ml.
- Large inner diameter ensures a high flow rate.
- Guarantees fast filtration and high samples throughput during routine testing.
- Quick performance of the filtrations required in the routine.
- For adapting to multi-branch use adapter A840.
TECHNICAL SPECIFICATIONS
Material Polypropylene Capacity 250 ml, 50 ml graduations Filter diameter 47 mm or 50 mm Filtration area 12.5 cm² Max. operating pressure Vacuum only Sterilization Ethylene oxide
ADAPTERS FOR POLYPROPYLENE FUNNEL TO MULTI-BRANCH SYSTEM 5.1. ADAPTER A840
DESCRIPTION
For adapting a polypropylene funnel on the multi-branch systems.
The stainless steel frit ensures uniform distribution of microorganismos and particles on the membrane filter surface.TECHNICAL SPECIFICATIONS
Material Stainless Steel AISI 304,B.S. 304S31
Gasket : Silicone flat gasket (41 x 50 x 1 mm)Filter diameter 47 mm or 50 mm Filtration area 12.5 cm² Max. operating pressure Vacuum only Sanitization By flaming Sterilization By autoclaving (134 ºC max.)
By dry heat (180 ºC)Outlet TR 20 x 2 mm male thread with DN 24 ( aprox. 24 mm) hexagonal nut
ORDERING INFO
A840 Single base for stainless steel manifolds RF102 Stainless steel frit, Ø 50 mm RF103 Stainless steel frit, Ø 47 mm RF124 Silicone flat gasket RF104 PTFE flat gasket RF274 Silicone O–ring