POLYETHERSULFONE SYRINGE FILTERS


DESCRIPTION

    

Recommended for fastest particle removal, purification and sterilisation of aqueous solutions and/or biological samples.

  • Incorporated polyethersulfone fixed without adhesive to a MBS polymerisate housing
  • Ready to use syringe filter
  • Hydrophilic
  • Low adsorption
  • Very High flow rates
  • Very Low flow resistance of the filter support
  • High total throughput even the most viscous proteinaceous solutions
  • Low hold-up volume
  • Minimun extractables
  • Up to 100 ml of sample
  • Large filtration area and an optimized geometry of the filter support
  • Luer Lock outlet making it possible to connect one syringe to another thus allowing serial filtration from larger to smaller pore size.
  • Pore size 0.10 µm to 0.45 µm
  • Easy pore size identification by coloured houses
  • Also available in individual sterile peel-packs
  • Not autoclavable, only feasible sterilization by gamma irradiation or ethylene oxide.


top ^


TECHNICAL SPECIFICATIONS

 
Syringe Filter
0.1 µm
Syringe Filter
0.2 µm
Syringe Filter
0.45 µm
Material filter
Polyethersulfone (PES)
Material house
Meta acrylate butadiene styrene polymerisate
Pore
0.1
0.2
0.45
Colour code
dark red
royal blue
yellow
Flow rate (1) ml/min
30
140
220
Bubble point
5
3.2
2.3
Filter diameter (mm)
28
28
28
Housing diameter (mm)
33
33
33
Filter area (cm²)
6.2
6.2
6.2
Hold up volumen (before/after bubble point)
0.3/0.15
0.3/0.15
0.3/0.15
Adsorption (2)
5 ug/cm² with BSA, 10 ug/cm2 with gamma globulin, 1.9 ug/cm² with insulin
Connectors
Female luer lock inlet
Male luer lock outlet
Cytotoxicity
No inhibition with MRC-5 or L-929 cells
Endotoxins
Endotoxins –output below the detection limit of the test (0.06 EU/ml)
Max. operational pressure (bar)
4.5
4.5
4.5
Busrt pressure (bar)
6
6
6
Max. temperature (ºC)
50
50
50
Sterilization methode in sterile version
Ethylene oxide

 

(1)  Flow rate for water at Ap = 1 bar ( 100kPa, 14.5 psi)
(2)  Wetting fluid: Isoporpyl alcohol
(3)  For pores size 0.2 µm.

top ^


APLICATIONS

  • Sterilizing of biological fluids, serum or aditives of tissue culture media, where low protein binding and low extractable are important
  • Sample preparation of aqueous solutions
  • Sample preparation of protein, where maximum sample recovery is essential
  • HPLC solutions.

top ^


ORDERING INFO

NON-STERILE

units /Pore
0.10 µm
0.20 µm
0.45 µm
100
-
JPES02025100
JPES04525100
500
-
JPES02025500
JPES04525500

 

STERILE

units /Pore
0.10 µm
0.20 µm
0.45 µm
50
JPESS0102550
JPESS0202550
JPESS0452550


top ^