CELLULOSE ACETATE SYRINGE FILTERS
DESCRIPTION
![]() |
Recommended for clarification, purification and sterilisation of aqueous solutions and/or biological samples. |
- Incorporated Surfactant-free Cellulose Acetate membrane fixed without adhesives to a MBS polymerisate housing.
- Ready to use syringe filter.
- Hydrophilic.
- Low adsorption.
- High flow rates.
- High total throughput.
- Low hold-up volume.
- Minimun extractables.
- Up to 100 ml of sample.
- Large filtration area and an optimized geometry of the filter support.
- Luer Lock outlet making it possible to connect one syringe to another, thus allowing serial filtration from larger to smaller pore size.
- Pore size 0.20 µm to 5.00 µm.
- Easy pore size identification by coloured houses.
- Disposable with a glass microfibre prefilter.
- Also available in individual sterile peel-packs.
- Not autoclavable, only feasible sterilization by gamma irradiation or ethylene oxide.
TECHNICAL SPECIFICATIONS
| Material filter | Surfactant-free Cellulose Acetate membrane |
|||||
|---|---|---|---|---|---|---|
| Material house | Meta acrylate butadiene styrene polymerisate |
|||||
| Pore | 0.20 |
0.45 |
0.65 |
0.8 |
1.2 |
5 |
| Colour code | blue |
yellow |
pink |
green |
red |
brown |
| Flow rate (1) ml/min | 60 |
160 |
250 |
350 |
400 |
500 |
| Bubble point | 3.2 |
2.0 |
1.3 |
0.8 |
0.7 |
0.4 |
| Filter diameter (mm) | 28 |
28 |
28 |
28 |
28 |
28 |
| Housing diameter (mm) | 33 |
33 |
33 |
33 |
33 |
33 |
| Filter area (cm²) | 6.2 |
6.2 |
6.2 |
6.2 |
6.2 |
6.2 |
| Hold up volumen (before/after bubble point) | 0.3/0.15 |
0.3/0.15 |
0.3/0.15 |
0.3/0.15 |
0.3/0.15 |
0.3/0.15 |
| Adsorption (2) | 0.8-3 ug/cm² with BSA, 8-12 ug/cm² with gamma globulin |
|||||
| Connectors | Female luer lock inlet Male luer lock outlet |
|||||
| Cytotoxicity | No inhibition with MRC-5 or L-929 cells |
|||||
| Endotoxins | < 0.06 EU/ml |
|||||
| Max. operational pressure (bar) | 4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
4.5 |
| Busrt pressure (bar) | 6 |
6 |
6 |
6 |
6 |
6 |
| Max. temperature (ºC) | 50 |
50 |
50 |
50 |
50 |
50 |
| Sterilization methode in sterile version | Ethylene oxide |
|||||
(1)Flow rate for water at Ap = 1 bar ( 100kPa, 14.5 psi)
(2)For pores size 0.2 um.
APPLICATIONS
- Sterile filtration of small volume liquids.
- Ultra-cleaning, purification, particulate removal and clarification of liquids.
- Sterile filtration and clarification of nutrient media, biological fluids, cell solution, proteins, enzymes serum or additives.
- Separation of virus /bacteria suspension.
- HPLC: Preparation of aqueous samples.
- Clinical applications: Sterile filtration of injected samples.
ORDERING INFO
NON-STERILE
| PORE units/box | 0.20 µm |
0.45 µm |
0.80 µm |
1.20 µm |
5.00 µm |
|---|---|---|---|---|---|
| 100 | JAC02025100 |
JAC04525100 |
JAC08025100 |
JAC12025100 |
JAC50025100 |
| 500 | JAC02025500 |
JAC04525500 |
JAC08025500 |
JAC12025500 |
JAC50025500 |
STERILE
PORE units/box 0.20 µm 0.45 µm 0.65 µm 0.80 µm 1.20 µm 5.00 µm50 JACS0202550 JACS0452550 JACS0652550 JACS0802550 JACS1202550 JACS5002550